Series | ESDD-450 |
Model | ESDD-370D | ESDD-450D |
Rated Output Power | 37Kw | 45Kw |
Rated Output Power | 75A | 90A |
Inflow Current | 76A | 92A |
Inflow Supply | Three-phase AC380V(-15%~+10%),50/60Hz |
Environment | Temperature | Operating Temperature:0 ~ +40℃(when ambient temperature is in 40℃~﹢ 50℃, please derate it in use) Storage Temperature: - 40 ~ + 70℃ |
Humidity | < 90% (Non-frosting) |
Vibration | < 0.5G(4.9m/S2) 10 ~ 60Hz (Non-continuous Operation) |
Control Mode | ①Position Control; ②Speed Control; ③Torque Control; ④Position&Speed hybrid control; ⑤Speed&Torque hybrid control; · ⑥Torque&Position hybrid control; · ⑦Pressure closed -loop control mode; · ⑧Position closed -loop control mode; |
Regenerative Brake | External Braking resistor(P+,PB);External Braking Unit(P+,(-)) |
Feature | Speed Frequency | ≥ 300Hz |
Speed fluctuation ratio | Below 0.03% (Load Fluctuation 0 to 100%,at Rated Speed ) |
Speed regulation ratio | 1:5000 |
Input Pulse Frequency | Differential input:0~500KHz Open collector input:≤200Kpps |
Control Input | Programmable IO input : 1、Servo enabled; 2、Alarm Clear; 3、CCW drive disenabled; 4、CW drive disenabled; 5、Deviation zero clearing; 6、Deviation zero clearing; 7、Zero -speed clamp; 8、CCW torque limitation; 9、CW torque limitation; 10、Control mode switchover; 11、 Internal position select 1,; 12、Internal position select 12; 13、Internal position select 3; 14、Internal speed select 1; 15、Internal speed select 2; 16、Internal speed select 3; 17、Internal torque select 1; 18、Internal torque select 2; 19、Gear ratio select 1; 20、Gear ratio select 2; 21、Speed direction select 1; 22、Speed direction select 2; 23、Speed direction reverse; 24、Emergency stopping; 25、Move to "Home"; 26、Reference “Home”sensor; · 27、Starting signal of internal position; · 28、Oil pressure control PID parameter selection; |
Control Output | Programmable IO output: 1、Servo Ready; 2、Servo Alarm; 3、Position Completed; 4、Electromagnetic Brake; 5、Speed reached; 6、Torque reached; 7、DSZR completed; 8、Zero speed signal; 9、Double-discharge plunger pump switchover signal. |
Position Control Mode | Input Pulse Type | ① Pulse + Direction;② CCW Pulse /CW Pulse;③Two-phase orthogonal pulse |
Electronic Gear | Setting Range: 1 ~ 65535/1 ~ 65535 |
Feedback Pulse | Adjustable According to the Encoder |
Internal position mode | Eight built-in position command set by parameters. |
Speed Control Mode | ① Eight built-in speed set by parameters; ②External Analog Input (DC-10V~+10v) |
Torque Control Mode | ① Four built-in torque set by parameters; ②External Analog Input (DC -10~+10V) |
Acceleration / Deceleration Function | The external coder or grating ruler can realize full-closed loop control of position |
Torque limit Function | 3 ways of External Analog Input (DC -10~+10V) |
Monitoring function | Adjustable by Parameters:1 ~ 10000ms(0 ~ 1000r/min or 1000 ~ 0r/min) |
Protection function | Torque Limit Range:-300 ~ +300% |
Display and Operation | Motor speed, current position, command pulse accumulation, Position deviation,Motor torque, Motor current,Rotor position, command pulse frequency, Control mode, IO signals,etc. |
Applicable Load’s Moment of Inertia | Short circuit detection,Input/Output phase-break protection,Overspeed, Overvoltage, Undervoltage,Overheating, Overload,Encoder anomaly, position |
Communication | 6 -digit LED Digitron,9 keys, 1 LED Lights,Support shift operation. User can freely define shortcut menu. |
Speed Control Mode | Less than 2.5 Times of Motor inertia |
Torque Control Mode | CAN,RS485 |
Acceleration / Deceleration Function | CE Accreditation 、FCC Accreditation |